c30.gif (28163 bytes)
Program Controller C30

A furnace is only as good as its controller allows it to be. To exploit the full performance of our furnaces, all switch and control units are matched to the individual furnace models and also to the requirements of our customers in an optimum manner. 

The new generation of program controllers C30 and C40 permit not only optimum process control, but are also distinguished by their simple, straight forward operation and comprehensive features. 

c40.gif (32265 bytes)
Program Controller C40 
globe2.gif (1030 bytes)Control of an extra function (4A, 230 V) which can be switched on during the process, e.g. for ventilation flap, cooling fan, catalyst etc.
globe2.gif (1030 bytes)Automatic timer for programmable switch-on or start time.
globe2.gif (1030 bytes)LCD display with 4 text lines of 20 characters each.
globe2.gif (1030 bytes)Adjustable control parameters.
globe2.gif (1030 bytes)Programming of date and time.
globe2.gif (1030 bytes)Digital interface RS 485 for linking to a PC.
Program Controller C40 extras :
globe2.gif (1030 bytes)Control of 2 extra functions (4A, 230 V).
globe2.gif (1030 bytes)Installation in wall-mounted or free-standing cabinet.
globe2.gif (1030 bytes)Suitable for multi-zone control with digital setpoint transmission.
globe2.gif (1030 bytes)Suitable for various thermocouple inputs K (N), S
 
c6d.gif (8082 bytes)
Program Controller C6 D
 
c5.gif (10302 bytes)

Program Controller C5

 

 
Program Controller C5 or C6 D

Many applications require just one programmable heating-up ramp and ore adjustable dwell time to run the whole process. Nabertherm can offer optimum solutions even for this purpose. The Program Controller C5 or C6 D offers precisely what's needed for simple applications: one heating-up ramp and one dwell time. With this you acquire a favourably priced, practice-orientated temperature controller which is naturally matched to the requirements of our furnaces and offers the quality features you can expect from Nabertherm.

Features : 

globe2.gif (1030 bytes)Extremely simple and staight forward operation.
globe2.gif (1030 bytes)Programmable heating-up ramp and dwell time.
globe2.gif (1030 bytes)Thermocouple input type K (N) or S.
globe2.gif (1030 bytes)Various electronic safety devices.
globe2.gif (1030 bytes)Installation in wall-mounted or free standing cabinet.
Program Controller C5 (400V) / S5 (230V) extras :
globe2.gif (1030 bytes)Programmable start delay time.
globe2.gif (1030 bytes)Mounted directly on the furnace.
globe2.gif (1030 bytes)C5 with key-operated switch, S5 with rocker switch.
 
p6apop.gif (10202 bytes)
Program Controller C6

Furnace according to the a.m. description with Controller C6 and seperate On - / Off - switch. 

globe2.gif (1030 bytes)Operation - friendly, dust-proofed foil keyboard.
globe2.gif (1030 bytes)Exact programming in steps of 1 degree celcius resp. 1min .
globe2.gif (1030 bytes)Adjustable time for one heating-up ramp.
globe2.gif (1030 bytes)Pre-adjusted (changeable) regulating parameters.
globe2.gif (1030 bytes)Several electronic safety components.
globe2.gif (1030 bytes)Thermocouple - inputs type K (1200 degrees celcius) or type S (1400 degress celcius).
 
PCc18.gif (20817 bytes)
Program Controller C18
Program Controller C18
 
globe2.gif (1030 bytes)Especially for melting and holding furnaces
globe2.gif (1030 bytes)Controller for temperature in furnace cavity and melt
globe2.gif (1030 bytes)7-day-preselective timer
globe2.gif (1030 bytes)Power indication
globe2.gif (1030 bytes)Alarm contact
globe2.gif (1030 bytes)Thermocouple PtRh-Pt, type S and NiCr-Ni, type K for melt
 
PCc19.gif (21386 bytes)
Program Controller C19
Program Controller C19
 
globe2.gif (1030 bytes)Programmer for 6 program steps (ramp or holding time)
globe2.gif (1030 bytes)Storage for 9 programs
globe2.gif (1030 bytes)3 programs can be combined to have a 18-steps-program
globe2.gif (1030 bytes)Automatic switch-on
globe2.gif (1030 bytes)Extra function to switch a fan
globe2.gif (1030 bytes)Thermocouple PtRh-Pt, type S
 
Controller B 170
p6bpop.gif (23536 bytes)

Controller P 320
p6bpop.gif (23536 bytes)
 
globe2.gif (1030 bytes)Very easy to operate.
globe2.gif (1030 bytes)Dust proof foil key pad.
globe2.gif (1030 bytes)Controlled by microprocessor.
globe2.gif (1030 bytes)Precise regulation: reproducible accuracy better than 3 degrees celcius.
globe2.gif (1030 bytes)Programmable in steps of 1 degree celcius and 1 min.
globe2.gif (1030 bytes)Storage for 9 programmes with each 4 ramps and holding times.
globe2.gif (1030 bytes)Accoustic alarm can be switched on and off automatically.
globe2.gif (1030 bytes)Earth contact female plug 230 V - 10 A at the rear of the furnace to connect fan or other extra function.
globe2.gif (1030 bytes)Max. 3 programmes can be combined.
globe2.gif (1030 bytes)Realtime clock for programming of a starting time (day, hour, min)
globe2.gif (1030 bytes)Thermocouple type K (L3/S - L9/S) or type S (L3/SH - L9/SH)
globe2.gif (1030 bytes)Integrated solid state relay
globe2.gif (1030 bytes)Delivered ready for use with 2 m cable and earth contact plug
globe2.gif (1030 bytes)Designed for professional use
 
 
Request your detail data information from info@acmecom.com